GLASS JACKETED PIPE SECTIONS

For heat of piping and for controlling the temperature throughout the column, the jacketed pipe sections are provided. Glass jacket is sealed to the pipe section using Viton 'O' ring and other sealing compositions. The seal prevents impermissibly high stresses between two tubes and allows the movement, which comes due to thermal expansion. Maximum operating pressure in the jacket:

DN 80 - DN 150 - 1.0 bar
DN 225 - DN 300 - 0.5 bar

Cat.Ref.

DN

L

d

DN1

J

J1

PSD3/1000

80

1000

100

25

850

750

PSD4/1000

100

1000

150

25

850

750

PSD6/1000*

150

1000

225

25

850

700

PSD9/1000

225

1000

300

25

850

700

PSD12/1000

300

1000

400

25

850

650