IMMERSIONS

Immersion heat exchangers are used to control exothermic reaction in glass vessels. They  can be used with vessels having wider bottom outlet (type VSR and VSE). These are provided with a central hole through the coil battery so that a special, extended type, stirrer can  be fitted which extends to the bottom of heat exchanger and provide thorough action.

In most applications, cooling water is used in coils (max. pressure 2.7 bar g.), but they can also be used with steam (max. pressure 3.5 bar g.). In latter case the coils must be completely immersed in liquid. Immersions are not recommended for use with products which have a tendency to crystallize.

Cat.
Ref.

DN

DN1

DN2

L

L1

d

H.T.A.

HEM6

150

40

25

200

200

145

0.4

HEM9

225

40

25

300

200

200

0.6